Roslyn Crescent

title in here title in here title in here title in here title in here title in here title in here title in here title in here title in here title in here

Southern Comfort Mechanical was approached early during the planning stages of this project to consult on the most optimal way to heat the new home. A geothermal system with fan coils and radiators was initially explored, but initial calculations showed that a large number of radiators would be required.

Design Challenge:

The client requested an HVAC system to be designed with minimal airflow throughout the home. The architectural drawings made no provisions for ductwork.

Solution:

Southern Comfort Mechanical worked with the client and General Contractor to design an HVAC system utilizing geothermal radiant floor heat throughout the entire home. A concrete slurry was poured over the installed floor tubing. Each level is controlled with a dedicated manifold, with a total of  five separate zones throughout the home.

Although the home is built in an existing neighborhood, the heat loss calculations and ground loop design showed that the lot size was large enough to allow for a vertical loop geothermal system. Ground loop was installed in the front yard and back yard to a depth of 50 ft.

 

 

 

← Back to Residential Projects